HPLC Column, Diamond Hydride 2.o, 2.2um, 3.0mm ID x 150mm Length, 120A. Cogent TYPE-C Brand. 1 EA.
Additional Info:
High‑Efficiency Diamond Hydride™ 2.o Performance in a Solvent‑Saver Format
The 70200‑15P‑3 Diamond Hydride™ 2.o HPLC Column is a custom‑manufactured analytical column engineered to deliver high efficiency and fast equilibration while reducing solvent consumption and operating pressure. Built on Cogent TYPE‑C™ silica hydride technology with a 2.2 µm particle size, this column provides near‑UHPLC performance using conventional HPLC systems.
The 3.0 mm ID × 150 mm length format occupies a highly effective middle ground between traditional 4.6 mm analytical columns and narrow‑bore 2.1 mm LC‑MS columns—offering improved efficiency and solvent savings without the stringent low‑flow requirements of narrower formats.
Why the 3.0 mm × 150 mm Configuration Is Selected
This column format is intentionally chosen for laboratories seeking improved performance with minimal system constraints:
Substantially reduced solvent consumption compared to 4.6 mm ID columns
Comparable run times to standard analytical columns at lower flow rates
Lower backpressure while maintaining high plate count
Straightforward compatibility with conventional HPLC instrumentation
For many laboratories, the 3.0 mm ID configuration serves as an ideal “solvent‑saver” analytical column that improves efficiency without requiring UHPLC hardware or extreme low‑flow capability.
Diamond Hydride™ 2.o Stationary Phase Advantage
The Diamond Hydride™ 2.o stationary phase is manufactured using Cogent TYPE‑C™ silica hydride technology with smaller 2.2 µm particles, providing advantages over both traditional HILIC phases and larger‑particle hydride materials:
Faster equilibration between injections
Increased column efficiency and sharper peak shapes
Stable and reproducible retention at high organic content
Mixed‑mode interaction capability for challenging polar analytes
These features enable high‑resolution separations with excellent robustness under routine analytical conditions.
Ideal Applications
The 70200‑15P‑3 Diamond Hydride 2.o column is routinely used for:
Small, highly polar molecules
Amino acids and organic acids
Polar and moderately non‑polar peptides
Metabolites and other biologically relevant compounds
It is especially well‑suited for laboratories transitioning toward higher efficiency methods without converting fully to UHPLC platforms.
High‑Resolution HPLC and UV Detection
The 150 mm column length provides increased plate count and resolving power, making this column effective for:
Analytical methods requiring improved resolution over shorter columns
Routine and validated workflows where reproducibility and robustness are critical
UV‑based detection using standard flow cells and detector configurations
Unlike narrow‑bore columns, the 3.0 mm ID format maintains comfortable injection volumes and detector compatibility.
LC‑MS Compatibility
While optimized for conventional HPLC workflows, the 70200‑15P‑3 is fully LC‑MS compatible where moderate analytical flow rates are acceptable. It is commonly selected for LC‑MS methods when solvent reduction and efficiency gains are desired without adopting 2.1 mm low‑flow constraints.
Operating Guidelines and System Requirements
Typical flow‑rate range: ~0.4–0.6 mL/min (method‑ and solvent‑dependent)
System compatibility: All standard analytical HPLC systems
Special requirements: No specialized low‑flow capability required
Flow rates may be optimized further based on resolution targets, pressure limits, and detector configuration.